某電器產品電源軟線上裝有RCD(剩余電流裝置,俗稱漏電保護器,見圖1)是否符合GB?4706.1-2005標準24.2條款“器具不應裝有在柔性軟線上的開關或自動控制器”的要求?
圖1 電源軟線上有RCD(剩余電流裝置)
2020年12月IEC/TC61國際電工委員會第61家用電器技術委員會網絡全體大會討論了這個問題,決議是不可以接受,詳見附件。
附件:
IEC/TC61 2020 web meeting
Reference 參考號 | Date 日期 | Provided to 提交至 | ||||||
KR-01(Webmeetings 2020) | 2019.11.06 | AG 28 | ||||||
Standard 標準 | Subclause(s) 條款 | Keywords 關鍵詞 | ||||||
60335-1:2010+AMD1:2013+AMD2:2016 | 24.2 and 25.2 | Means of connection to the supply mains – switches –automatic controls 連接電源的方式–開關–自動控制 | ||||||
Question 問題 | ||||||||
RCD(PRCD) has functions: There is a temperature controlling device at the end of the power supply cord which enters the appliance and the RCD is installed in the power supply cord as shown in the photo. The reset button (I) and the test button (T) of the RCD are considered to check whether the RCD(Residual current device) is operating normally. For example, do not use the product if the test function fails (when the indicator light does not turn off). RCD(PRCD)具有以下功能: 如圖所示,電源線末端有一個進入設備的溫控裝置,RCD安裝在電源線中。 RCD的重置按鈕(I)和測試按鈕(T)用于檢查RCD(剩余電流設備)是否正常運行。 例如,如果測試功能失敗(指示燈不熄滅),請勿使用產品。 2st Question This appliance is fitted with PRCD in flexible cord. PRCD is tested by IEC 61540. I think it is not complied with clause 24.2 because it seems like switches or automatic controls, but I got a different opinion. It is not switches and controls. So it is complied with clause 24.2. Please give me your decision whether this product is complied with clause 24.2 or not. 問題2 器具在軟線中裝有PRCD。PRCD已通過IEC 61540的測試。 對此有不同的意見: 1、它看起來像是開關或自動控制器,因此不符合第24.2條的要求 2、它不是開關和自動控制器,因此符合第24.2條的規定。 請確定該產品是否符合第24.2條的規定。 | ||||||||
AG 28 Answer AG28主席顧問團回答 | ||||||||
2st Question Clause 24.2 prohibits PRCDs being fitted in flexible cords; please also see an enclosed response already confirmed by IEC TC 61 for a similar case. 問題2 第24.2條禁止將PRCD安裝在軟線中;另請參見附件IEC TC 61已確認的類似情況的回復。(見下文) | ||||||||
TC 61 Decision IEC/TC61決議 | ||||||||
Confirmed 確認。 |
3、標準條款
GB 4706.1-2005《家用和類似用途電器的安全 第1部分:通用要求》標準
24.2 器具不應裝有:
——在柔性軟線上的開關或自動控制器;
——如果器具出現故障,引起固定布線中保護裝置動作的裝置;
——通過釬焊操作能復位的熱斷路器,除非焊料的熔點至少為230℃。
通過視檢檢查其符合性。
IEC 60335-12010+AMD1:2013+AMD2:2016《家用和類似用途電器的安全 第1部分:通用要求》標準
參考譯文:
24.2 器具不應裝有:
——在柔性軟線上的開關、自動控制器、電源適配器等類似設備;
——如果器具出現故障,引起固定布線中保護裝置動作的裝置;
——通過釬焊操作能復位的熱斷路器,除非焊料的熔點至少為230℃。
通過視檢檢查其符合性。